S3602C / D / E Vector Network Analyzer

(Frequency Range: 10MHz – 43.5GHz / 50GHz / 67GHz)

S3602 series VNA can be universally implemented in fields including transmission/reception module measurement, dielectric material property measurement, microwave pulse characteristic measurement and photoelectric property measurement; It is a necessary instrument in the scientific research, production process of systems like radar, communication and navigation. S3602 C / D / E are high level VNA products and can reach a higher frenquency range up to 67GHz

Key Features

  • Frequency coverage from 10MHz to 43.5GHz / 50GHz / 67GHz
  • Flexible calibration types, compatible with many calibration parts
  • Support Multi-window, multi-channel Measurement, instantly execute intricate measurement plan
  • Include multiple display formats including logarithmic amplitude, linear range, standing wave, phase, group delay, Smith circle map, polar coordinates
  • Support USB, GPIB, LAN, VGA
  • 12.1 inch high resolution touch screen
  • One button measurement to simplify the setup procedures and improve the working efficiency
  • Provide functions including Pulse S Parameter measurement, time domain measurement, mixer measurement, 2 dimensional measurement of gain compression, millimeter wave spread spectrum, antenna and RCS measurement reception.

Typical Applications

  • Mixer Test
  • Filter Test
  • Integrated Pulse S Parameter Test

Technical Specifications

Frequency characteristic
Frequency Range S3602C: 10MHz - 43.5GHz
S3602D: 10MHz - 50GHz
S3602E: 10MHz - 67GHz
Frequency resolution 1Hz
Frequency Accuracy ±1×10-7(23℃±3℃)
Output & Dynamic Range
Max. Output Power S3602C: 11dBm
S3602D: 11dBm
S3602E: 8dBm
Max. Dynamic Range S3602C: 121dB
S3602D: 121dB
S3602E: 110dB
Port Harmonic Suppression
Port 1, 3 Harmonic Suppression -51dBc(0.01-4GHz)
-60dBc(4-40GHz)
-60dBc(40-50GHz)
-60dBc(50-67Ghz)(Nom.)
Port 2, 4 Harmonic Suppression -13dBc(0.01-4GHz)
-21dBc(4-13.5GHz)
-60dBc(13.5-40GHz)
-60dBc(40-50GHz)
-60dBc(50-67Ghz)(Nom.)
Other
IF Bandwidth 1Hz-5MHz
Amplitude DisplayResolution 0.001dB/div
Phase Display Resolution 0.01°/div
Amplitude Reference Level 
Set Required Value
-500-+500dB
Phase Reference Level 
Set Required Value
-500-+500°
General characteristic
Port Connector Type S3602C/D:2.4mm(M), 50Ω system impendence
S3602E:1.85mm(M), 50Ω system impendence
Measurement of Ports S3602C/D/E:  2 Port,  Standard
S3602C/D/E-400:  4 Port, (Optional)
Peripheral Interface USB, GPIB, VGA, LAN
operating system Windows 7

General Information

Display Method 12.1 inch high resolution touch screen
Dimension (LxHxW) 426mm×266mm×600mm
(Including handles, pad foot and footing) 463mm×279.5mm×690mm
(handles, pad foot and footing are not included)
The Maximum Power Consumption 500W
Maximum Weight S3602C / D:47kg
S3602E:50kg

Main machine

Part No. Frequency Range
S3602C 10MHz – 43.5GHz
S3602D 10MHz – 50GHz
S3602E 10MHz – 67GHz